teriary butyl isocynide Wed Oct 18 20:56:29 2017 -------------------------------------------------------------------------------------========= obs o-c error blends Notes o-c wt / instead of : below denotes (o-c)>3*err -------------------------------------------------------------------------------------========= 1: 1 0 0 0 0 1 5864.2705 0.0004 0.002 2: 1 0 2 0 0 1 5864.3396 -0.0010 0.002 3: 1 0 1 0 0 1 5864.3883 0.0006 0.002 -------------------------------------------------------------------------------- PARAMETERS IN FIT (values truncated and Nlines statistics): 10000 A /MHz [4500.] 1 20000 B /MHz [2932.174952] 2 -30000 C /MHz [2932.174952] = 1.00000 * 2 200 DJ /kHz [ 0.35377] 3 1100 DJK /kHz [ 4.13769] 4 110010000 chi.aa*3/2 /MHz 0.2352(53) 5 MICROWAVE AVG = -0.000009 MHz, IR AVG = 0.00000 MICROWAVE RMS = 0.000740 MHz, IR RMS = 0.00000 END OF ITERATION 1 OLD, NEW RMS ERROR= 0.36996 0.36996 distinct frequency lines in fit: 3 distinct parameters of fit: 1 upper state lower state overall limits of quantum number 1: 1 1 0 0 0 1 limits of quantum number 2: 0 0 0 0 0 0 limits of quantum number 3: 0 2 1 1 0 2 frequency range: 5864 5864 PARAMETERS IN FIT WITH STANDARD ERRORS ON THOSE THAT ARE FITTED: (values rounded and degrees of freedom, Ndegf=Nlines-Nconst, statistics) 10000 A /MHz [4500.] 1 20000 B /MHz [2932.174952] 2 -30000 C /MHz [2932.174952] = 1.00000 * 2 200 DJ /kHz [ 0.35377] 3 1100 DJK /kHz [ 4.13769] 4 110010000 chi.aa*3/2 /MHz 0.2352(24) 5 CORRELATION COEFFICIENTS, C.ij: chi.aa*3 chi.aa*3/2 1.0000 No correlations with absolute value greater than 0.9950 Worst fitted lines (obs-calc/error): 2: -0.5 3: 0.3 1: 0.2 2: 1 0 2 0 0 1 5864.3396 -0.0010 0.002 3: 1 0 1 0 0 1 5864.3883 0.0006 0.002 1: 1 0 0 0 0 1 5864.2705 0.0004 0.002 _____________________________________ __________________________________________/ SPFIT output reformatted with PIFORM