1. Introduction
1.1. Backscattering Theory and its Applications
When a -particle enters a material its path can be deflected when it interacts with the nuclei of the material. The -particles are oppositely charged to the positively charged nucleus and thus an attractive force exists between the two. The deflections that result are dependent on the initial energy of the -particles but the effect is of a general scattering of the particles. This usually has the effect of changing the forward direction of a -particle by a few degrees, but occasionally if the -particle is suitably orientated in relation to the nucleus, the will be deflected through a value of around resulting in it exiting the material from the same side as it entered [1]. It is this phenomenon that is known as backscattering.
For thick samples, as yet no theoretical relationship exists on -particle backscattering due to the complexities of calculations involving multiple scattering. That is to say when a -particle enters a material it may scatter off many different atoms before leaving the material and thus the idea of backscattering being uniquely an interaction between one -particle and one atom breaks down. In certain cases relationships developed to deal with single scattering can be used as a possible approximation to what is actually happening. In any case the relationships that do exist concerning backscattering are purely empirical.
Beta particle backscattering has been a subject for investigation for many years; yet data, theoretical or experimental, on any relationships between atomic number ( number) of the scatterer, the angle of scattering and the count rate, is sparse. The subject has been mainly of interest to physicists involved in the laws of charged particle scattering and those developing devices such as -ray thickness gauges.
The recent increase in the availability and use of high-energy electron accelerators has caused a necessity for greater understanding of the above ideas.
Specific examples of the applications are in the use of radiation therapy for the treatment of tumours and in Computer Aided Tomography Scanners (more commonly known as CAT scanners). Understanding -ray backscattering becomes useful in attempting to target tumours with greater accuracy and in the optimal use of data gained from CAT scanners. This is due to the fact that the density of tissue is far from even throughout the human body and at high/low density boundaries -ray backscattering becomes a significant factor in determining the absorbed dose of the surrounding tissues. Unfortunately due to theoretical complexities no satisfactory theoretical solution to the practical application of -ray backscattering has as yet been published.
2. Initial data
Before the main aims of the investigation can be tackled there are a few preliminary experiments that have to be completed to give information on the equipment and source that it is proposed to use. In many cases in this investigation the raw data obtained is itself of little interest. In this circumstance only the graphs of the data have been included.
2.1. Transmission through air of a collimated source (Sr-90)
This experiment was to determine the order of the size of separations that could be used between the source/scatterer and scatterer/Geiger Müller (G-M) tube. From the graph of this data (Fig. 1) it can quite clearly be seen that once the distance between the source and the detector has exceeded approximately 0.40 m the count rate has fallen almost onto the -axis. Such separations are therefore not acceptable as there are not a significant number of -particles to count. In addition if the total separation is less than approximately 0.05 m the number of counts per minute changes so rapidly with the separation that there is an excessive error in the count due to any error in positioning. For accurate results in the further experiments it would be wise to keep the total distance between source and detector to a value inside these limits.
This graph is used in later experiments to estimate the counting error due to any error in the distance between the source and the G-M tube. See Appendix A for a further explanation of errors.
The fall in the count rate as the source/detector separation increases is possibly due to the scattering of the -particles as they travel through the air. Assuming that the source is perfectly collimated we would expect the following relationship, based on the theoretical idea of scattering in Fig. 2:
(1) |
As formula (1) suggests the relationship between count rate and distance is indeed an exponential decay but as can be seen from the graph (Fig. 3) the decay is not just one exponential curve but two.
This is very probably the result of the two-stage decay process of
strontium-90, shown below [2]
The decay process gives out a spectrum of energies with a finite limit that depends upon the element and thus having two decays provides two separate spectra of -particle energies. Therefore the two different maximum energies will be predominant in affecting the transmission at different distances and thus possessing different values of , the scattering coefficient.
2.2. Variation of count rate with angle of detection
Another important factor to investigate was the imperfection of the collimated beam of the source. The procedure was to record the count rate at a fixed distance from the source and to vary the angle from the normal at which the readings are taken. A diagram of the experimental set-up is shown in Fig. 4 with the graph of the results in Fig. 5.
Due to the reasonably large spread in angle which is detected by the G-M tube this source is reasonably well collimated.
3. Angular dependence of scattering
The initial experiments were carried out using aluminium with the experimental set-up shown in Fig. 6 [3].
3.1. -particle backscattering with aluminium
The initial data collected (Table I) was of more qualitative than
quantitative value, as it became apparent that the count rates were not
significant in comparison to the background rates. All the counts were
measured over 180 seconds.
Background | Al sheet thickness [mm] | Angle | Count |
2.03 | 10 | 193 | 174 |
2.03 | 20 | 124 | 149 |
2.03 | 30 | 111 | 111 |
2.03 | 40 | 95 | 75 |
50.00 | 10 | 175 | as above |
50.00 | 20 | 116 | as above |
There were a few solutions to the problem. Firstly, if the total source/detector separation was reduced then the count rate should increase considerably (based on the ideas developed earlier concerning the scattering of -particles through air and the imperfections of the collimated beam). Due to the rather bulky shapes of source holder, a clamp stands and the detector, a 10 measurement would no longer be possible if the apparatus was moved closer together. The other main option was to change the scattering material to something with a higher atomic number, which according to theory, should scatter a greater proportion of -particles and thus increase the counting rate. It was the latter of these two options that was chosen first.
3.2. -particle backscattering with lead
The experimental set-up was only changed from the previous experiment with aluminium by the following:
The angular dependence of backscattering could be seen with this set-up but the errors were too great to conclude reliably any more than this. The experiment was repeated but this time the total distance that a -particle had to travel was substantially reduced. As the apparatus was so much closer together no measurement could be taken for an angle of 10. The source/lead scatterer distance was 55 mm; the scatterer/G-M tube distance was 60 mm. The graph (Fig. 7) was obtained from the results. The duration of each count was 300 seconds.
The points on the graph are bounded by two curves of the form
The value of the constant in the figure is chosen approximately, determined from the fit of the data of Knop and Paul to the curves. Thus the above curves should relate as closely as possible to the data in this experiment.
Another set of results was obtained to check the repeatability of the experiment and thus the validity of the conclusions. The graph of the results is shown in Fig. 8. The counts were measured over 180 seconds.
As can be seen from both of these graphs of backscattering against angle, although the points fit reasonably well inside the limits set by the and curves they actually fit a linear equation much more accurately (seen from the points' proximity to the linear regression line).
A simplified formula for the backscattering of mono-energetic electrons was
given by Bethe et al. [5]
An interesting result is discovered if a graph of this formula is drawn and the line of best fit found for the data range used in the last two experiments ( ). What is found, shown in Fig. 9, is that the points lie very close to a straight line compared with the range given by the cosine estimates. This is purely a qualitative observation but it illustrates clearly that although the small amount of research that exists suggests that the data should follow some sort of cosine or cosine squared fit, over the range that was used in the experiments in this investigation, the fit is very nearly linear. It can therefore be said with some certainty that there does exist an approximately linear relationship between the count rate and the backscattered angle over the range .
4. Atomic number dependence
As has already been suggested there is a connection between the atomic number ( number) of an element and its ability to produce high backscatter count rates. These ideas were tested using equipment in the University of Edinburgh's First Year Physics teaching laboratories. The experimental set-up is shown in Fig. 10.
The samples that were initially used for backscattering were cylinders of approximately equal diameter of the following elements: carbon, aluminium, iron, copper, indium, tin, tungsten, lead. Similar cylinders of polythene (CHCH), iron oxide, potassium chloride, sand (SiO) and glass (taken as SiO) were also used at this stage to see how simple compounds might fit the relationship.
Previous work on this topic has suggested an empirical linear relationship
between the count rate and . In addition Baily (1980) [6] found
that much backscattering data could be fitted empirically with a
dependence. An approximation to for compounds is calculated as the
sum of the relative proportions of each constituent element multiplied by
the logarithm of its atomic number. A similar calculation is used for an
approximation to . After briefly testing the experimental set-up
to see if some sort of relationship was visible from the results the tin
cylinder was arbitrarily chosen to find the optimum distance from the source
to achieve the highest count rate. It can quite clearly be seen from the
diagrams in Fig. 10 that if the scatterer was placed too close to the
source/G-M tube holder virtually no -particles would be able to
enter the G-M tube from the scatterer. Also if the scatterer is too far
away from the source and G-M tube, the -particles will be scattered
by the air; thus there must be an optimum separation.
Separation [mm] | Count |
8 | 419 |
11 | 492 |
12 | 463 |
13 | 507 |
14 | 488 |
15 | 443 |
18 | 424 |
23 | 367 |
28 | 288 |
33 | 269 |
38 | 178 |
Table II shows that the highest count is with a separation of mm. As the most accurate measurement that can be made is mm it is quite acceptable to use 13 mm as the optimum separation without drawing a graph of the results. This separation is used in all further experiments (Figs. 11 to 15). The measurements in the following experiments were taken over 300 seconds.
On returning to use the school equipment a new experimental set-up was arranged and all the samples used were in solid form, as opposed to powders. They were: lead, copper, iron, aluminium, phosbronze (92% Cu, 8% Sn), perspex (CHCCHCOOCH), copper sulphate (CuSOHO), calcite (CaCOHO).
Two sets of experimental data were collected and the relevant graphs are shown in the figures. All measurements were taken over 180 seconds. These results (Figs. 14 and 15) used lead, iron, aluminium, phosbronze (92% Cu, 8% Sn), perspex, glass, a copper sulphate crystal (CuSOHO) and a calcite crystal (CaCOHO).
The regression lines are drawn through the element points as they seem to give a reasonably consistent line as shown by the graphs in Figs. 11 and 12. This allows explanation of the counts from the compounds. The phosbronze has a larger calculated number and fits the line reasonably well but the compounds with smaller numbers appear quite remote from the line. This can be explained to some extent by referring to Fig. 12 where there are counts on both carbon graphite and polythene. The point to note is that although the ratio of hydrogen to carbon in polythene is 2 : 1, the polythene points are only just lower than that of the pure carbon. This suggests that hydrogen may not fit the relationship very well. This is not unreasonable as the relationship is only an empirical one and hydrogen being the lowest extreme would be the most likely point not to fit. What is interesting is that if the calculation for the calcite and copper sulphate is performed without adding in the water of crystallization the values are respectively, 1.01 and 1.09, which are exceedingly close if they do not intersect the line.
5. Conclusion
The angular dependence of -particle backscattering has been clearly shown to form a linear relationship over the range that was used. This does in fact agree well with the published ideas on the subject, which tend favour a relationship with a cosine fit, as the curve is very closely linear over the range that was used in the experiments.
The dependence of backscattering is a subject with little research background yet it was certainly obvious that for elemental scattering samples that they fitted a logarithmic relationship. The relationship was an improvement when simple compounds were added to the scattering samples. The graphs showed that the compounds must follow some sort of a similar relationship but calculating a value for some of them proved inaccurate, mainly due to the fact that hydrogen atoms seemed to have less influence than the relationship suggested.
Both of these subject areas are heavily lacking in any published data and all relationships that do exist are of an empirical nature. This is not surprising as the idea of single scattering is amenable to calculation but by using a thick sample to achieve backscattering, the multiple scattering of the -particles that becomes possible prevents any further theoretical treatment of the subject.
The inaccuracies in the experiments could be greatly reduced by the use of more dedicated equipment that has been specially designed for a particular experiment although to go in search of such minimization was outside the scope of this investigation.
Acknowledgments
I would like to thank the physics staff and technicians for their help and patience especially when I was looking for obscure scattering samples in the store. I would also like to extend my thanks to the University of Edinburgh Physics Department for allowing me to use the First Year laboratories and equipment.
Appendix A
In general all errors that are shown in results tables are the total of all errors for a specific measurement and are also be included in any graph of the results. The only exception is where the errors are small enough to be included inside the diameter of the points plotted on the graph.
Errors in -particle counting are calculated from the Poisson distribution nature of the counts. Thus a count of in a particular time period has an associated standard deviation of .
Furthermore if the background is measured in time and the count
is over time , then the error in the corrected count can be found
to be
Added to this value (if it is significant) is an error associated with a total path distance between the source and the G-M tube. This error is approximate as it is calculated from the graph of the transmission of the -particles through air. The error in the positioning of any object is half of one scale division of the instrument used for the measurement. Generally in this investigation this error is mm and thus for most of the experiments the total distance error is mm split between: 0.5 mm for each of the source and G-M tube, and 1.0 mm for the scattering material (it is counted twice since its positioning changes two distances). Using this error in distance in conjunction with the graph mentioned and over the limits, m, an error in the count due to the error in positioning can be found, which is generally of the order of 5%.
The value of the error in the angular measurement is taken as the angle subtended by the G-M tube. That is to say, the inverse tan of the radius of the tube (9.5 mm) divided by the distance to the scattering material.
Appendix B
Gaussian distribution of disintegration
measurements
This experiment was performed as a demonstration of the normal approximation to the Poisson distribution of measurements of -particle disintegrations [7]. This leads to the standard deviation in the count being equal to the square root of the count as discussed in Appendix A. The idea was to take twenty measurements of the number of disintegrations from the Sr source over a time duration and separation that would give counts of around 100. The experiment were then repeated using a duration ten times the size so as to obtain counts of around 1000.
For clarity the results are not included; instead the results are represented as histograms of the number of counts in each standard deviation away from the mean (Fig. 16). Plotted alongside each bar is the expected number of counts calculated using the Gaussian distribution. For the purposes of these results the percentage deviation is percentage difference in the expected count when one moves one standard deviation away from the mean.
(Fig. 16a)
|
(Fig. 16b) |
For the counts taken over 30 s the mean of the results is 119 with standard
deviation 11.
Therefore the percentage deviation in these
results is
For the counts taken over 300 s the mean of the results is 1089 with
standard deviation 33. Therefore the percentage deviation in these results
is
Thus by comparison with the 30 s results it is clearly demonstrated that by increasing the size of the count, the spread about the mean is reduced greatly.